945 Boulevard du 30 Juin, Gombe, Kinshasa, Democratic Republic of the CongoFrançais
AXORA technical visualisation illustrating Electrical

ELEC · AXORA EXPERTISE

Electrical

Distribute safe, available and measurable energy from the source to every load.

Building electrical system studies and coordination, from switchboards to final circuits, with a strong focus on maintainability.

RevitAutoCADDIALuxETAP
AXORA TECHNICAL VISUALISATION — ILLUSTRATIVE IMAGE

DISCIPLINE OUTCOMES

Expertise tied to actual building performance.

AXORA structures electrical distribution as a complete system: loads, architecture, protection, continuity, lighting, earthing, metering, controls, coordination and testing.

01

Electrical safety

Protection against shock, overcurrent, faults, surges and environmental risks.

02

Service continuity

Load segregation, priorities, standby power, UPS systems and recovery strategies.

03

Quality of use

Lighting, outlets, controls and distribution adapted to use and maintenance.

04

Measurement and control

Metering, phase monitoring, load shedding, status and automation interfaces.

SYSTEM ARCHITECTURE

From input data to a tested system.

Each layer produces verifiable information for the next. Interfaces are resolved before construction and confirmed through testing.

01

Sources

Utility, transformer, generator, solar, batteries and UPS systems as required.

02

Main distribution

Main switchboards, busbars, selectivity, transfer and protection.

03

Sub-distribution

Distribution boards, risers, cables, containment and openings.

04

Final circuits

Lighting, outlets, specialist equipment, emergency circuits and controls.

05

Metering and tests

Metering, supervision, verification, testing and energisation records.

DESIGN INPUTS

No serious sizing without explicit inputs.

AXORA starts by qualifying available inputs, gaps and their impact. An assumption remains identified until confirmed.

  1. 01Load inventory and operating regimes
  2. 02Utility and standby-source characteristics
  3. 03Plans and room uses
  4. 04Criticality and required autonomy
  5. 05Installation conditions and temperatures
  6. 06Lighting, earthing and protection requirements

TECHNICAL CAPABILITIES

A complete scope adapted to the project stage.

The final content depends on the contract, confirmed inputs and requirements applicable to the project.

ELEC · 01

Load schedules and documented diversity

ELEC · 02

Single-line diagrams and standby architectures

ELEC · 03

Cable sizing and voltage drop

ELEC · 04

Short-circuit currents and protection coordination

ELEC · 05

Interior, exterior and emergency lighting

ELEC · 06

Earthing and equipotential bonding

ELEC · 07

Generator, UPS, solar and batteries

ELEC · 08

Metering, load shedding and energy supervision

MULTIDISCIPLINARY COORDINATION

Quality is decided at the interfaces.

AXORA treats dependencies between systems as design, construction and testing requirements.

HVAC and pumping

Loads, starting, drives, standby supply and run commands.

Fire safety

Safety supplies, shutdowns, status feedback and approved scenarios.

BIM and architecture

Rooms, clearances, openings, cable routes and maintainability.

Smart building

Lighting, metering, load shedding, status, scenes and trends.

AXORA METHOD

From intent to the as-built package.

01

Scoping and data

Confirm uses, boundaries, available data, requirements and responsibilities.

02

Design basis

Document assumptions, criteria, options and approval conditions.

03

Calculations and architecture

Size functions and structure systems before detailed design.

04

BIM coordination

Bring spaces, networks, equipment, access and interfaces into a coordinated model.

05

Construction package

Produce drawings, diagrams, details, schedules, quantities and specifications.

06

Delivery and control

Check equipment, layouts, installation, changes and document compliance.

07

Testing and commissioning

Verify every point, function and integrated scenario before acceptance.

08

Handover and maintenance

Provide as-builts, backups, training, instructions and a follow-up plan.

DELIVERABLES

Documents that support decisions, construction and maintenance.

Load schedulesSingle-line diagramsLighting and power layoutsCable schedulesBills of quantities

DOCUMENTED AXORA PROJECTS

Real project contexts, with no extrapolation beyond the documented scope.

The visuals below come from project files recorded on the site. Each project page states the documented scope; an image alone does not prove progress status or performance.

How to read the images

Discipline hero images are AXORA technical visualisations. Cards in this section correspond to documented projects. Construction or completed-work photographs will only be labelled as such after their source has been supplied and verified.

FREQUENTLY ASKED QUESTIONS

Points to clarify before design.

Why is a load schedule not enough?

It quantifies demand, but architecture, faults, voltage drop, selectivity, standby supply and installation conditions still require study.

Can the whole building be backed up?

Sometimes technically, but the strategy must compare criticality, power, autonomy, starting, fuel, cost and operation.

Does solar replace electrical protection?

No. Every source and operating mode requires a coordinated architecture and protection system.

Are international standards automatically applicable in the DRC?

No. The regulatory and contractual framework and competent authority must be confirmed before fixing the project standard.

TECHNICAL REFERENCES

Official sources with controlled applicability.

These resources support the method but do not automatically become the contractual framework for a project in the Democratic Republic of the Congo. Edition, scope and applicability are confirmed during scoping.

YOUR PROJECT

Let us turn your Electrical requirements into a coordinated, calculated and testable system.

WhatsApp